Summer Sale! Order 10 or more cases of consumables and get 10% off! Limited time only!

Sold out

Clickbio's VBLOK200 is designed as a low dead volume reagent reservoir for 8-channel pipetting and a centrifuge collection vessel for recovering liquid from multiwell plates.

  • 200 mL working volume (280 mL max)
  • <1 mL dead volume
  • Standard ANSI/SLAS automation footprint
  • Virgin Medical Grade Polypropylene
  • Optional E-beam sterilization
  • RNase, DNase, and Pyrogen free
  • Case of 24, individually wrapped.  

Sample Pooling and Recovery

The VBLOK200 was originally designed to recover or pool liquids in a multi-well plate. Just invert the plate into the VBLOK and spin in a centrifuge to collect all residual liquid in a 24, 96, 384, or 1536-well plate. This reduces tip costs, saves pipetting time, and improves recovery compared to manual or automated pipetting from each well.

With a dead volume of <1 mL, the VBLOK is also an ideal reservoir for automation workflows where reagent waste reduction is paramount.  

Popular applications include:

Low Volume Reagent Reservoir

Beyond its initial purpose the VBLOK is widely used as a reagent reservoir. The unique design funnels all liquid to the center where it is accessible for pipetting with an 8-channel pipette. The high-polish inner surface of the VBLOK ensures all liquid pools in the V-bottom channel.

 

Literature Reference:

Transcriptome dynamics of CD4+ T cells during malaria maps gradual transit from effector to memory

Nature Immunology | VOL 21 | December 2020 | 1597–1610 |

Specifications

Fill Volume

200 mL working volume (280 mL max volume)

Dead Volume

< 1 mL

Dimensions (LxWxH)

129.76 mm x 87.48 mm x 38.10 mm

Footprint

Standard ANSI/SLAS (127.76mm x 85.48mm)

Weight

35 g per plate

Material

Medical Grade Polypropylene

Configuration

V-bottom designed for 8-channel pipetting

Plate Compatibility

Standard and deep well plates (24, 96, 384, and 1536 well)

Centrifuge Compatibility

XXXX, XXXXX and XXXX

Sterile

RNase, DNase and Pyrogen free, Optional E-Beam Sterilization

Quantity Per Case

24 individually wrapped

Case Weight

1.5 kg

Literary References

Transcriptome dynamics of CD4+ T cells during malaria maps gradual transit from effector to memory


Nature Immunology | VOL 21 | December 2020 | 1597–1610 |

Applications

Next Generation Sequencing (NGS) Library pooling

Recovery of Antigen or Primary antibodies during Elisa plate preparation

Coating tissue culture plates

Low Volume Reagent Reservoir

Accessories / Related Products

These additional accessories expand the utility of the VBLOK200 and are designed to integrate seamlessly into the deck of your existing automated liquid handler.

Fill Station

Looking to add additional reagent capacity to the deck of your liquid handler? Don’t want to go through the hassle of integration and reprogramming? Need a sterile fluid path and recirculation? The Fill Station has it all!

The Bottomless Waste Station

Does your application generate large volumes of waste reagents? Add a vacuum trap and securely store the excess waste off deck.

VBLOK200 Adapter

Add temperature control and shaking to your reagent reservoir. Compatible with popular on deck heating, cooling, and shaking devices.

BACK TO TOP